Air leakage (E283), water penetration (E331 uniform, E547 cyclic, E1105 field), structural wind (E330) and windstorm impact/cyclic loading (E1886, E1996) are separate exposures. Specify the product, installation and the exact question before choosing.
Sample considerations
- ASTM E283/E283M: Product type, size, operation, installation condition and test pressure basis
- ASTM E331: Specimen, installation, pressure schedule and water application
- ASTM E547: Specimen, cyclic pressure schedule and leakage observation criteria
- ASTM E1105: Installed product, site access, interior/exterior conditions and pressure capability
- ASTM E330/E330M: Specimen size, anchorage, glazing and design/proof load objectives
- ASTM E1886: Missile type/energy, cyclic pressure schedule, glazing and frame build